- Ideal for use in general filtration or medical assays
- BSA protein binding capacity of 160 µg/cm², will bind a wide range of fragment sizes and can still be easily
blocked for low background
- High wick rates (lateral flow), substances move quickly through the membrane
- Uniform pore structure provides consistent flow and diffusion rates
- Superior strength, withstands aggressive handling or can be used with automated equipment without breaking or
tearing
- Exceptional sensitivity, detects low-level components
- Low extractables, which ensures tests will be clean and pure, leading to more consistent results
- Lot-to-lot consistency, quality checks produce dependable results every time
|
Applications
Medical Assays
- Common analytes detected
- Pregnancy (hCG)
- Chlamydia
- Strep A
- HIV
- LH
- Drugs of abuse
- Environmental contaminants
- Pathogenic microorganisms
- Detection methods
- Immunochromatographic assays
- Lateral flow immunoassays with latex beads
- Capillary immunoassays with colloidal gold
- Latex agglutination assays
- Immobilization
- Dot /slot blotting
- Direct spotting
- Direct line application with a line applicator
- Immersion and drying
Products
| Part # |
Model # |
Description |
Pore Size |
Filter Size |
Qty. |
Price |
 |
| 1225781 |
E04WP320F5 |
GE Nitrocellulose Mixed Esters Membrane |
0.45 micron |
200x200 mm |
5 |
$93 |
 |
| 1231466 |
E06WP00010 |
GE Nitrocellulose Mixed Esters Membrane |
0.65 micron |
300x3000 mm |
1 |
$297 |
 |
| 1215458 |
EP2HY00010 |
GE Pure Nitrocellulose Transfer Membrane |
0.22 micron |
300x3000 mm |
1 |
$275 |
 |
| 1215464 |
EP2HY320F5 |
GE Pure Nitrocellulose Transfer Membrane |
0.22 micron |
200x200 mm |
5 |
$108 |
 |
| 1215471 |
EP4HY00010 |
GE Pure Nitrocellulose Transfer Membrane |
0.45 micron |
300x3000 mm |
1 |
$249 |
 |
| 1215477 |
EP4HY320F5 |
GE Pure Nitrocellulose Transfer Membrane |
0.45 micron |
200x200 mm |
5 |
$100 |
 |
|
Product Description
GE Nitrocellulose Mixed Esters (MCE) membrane is an unsupported, naturally hydrophilic membrane. It is ideal for use in diagnostic kit manufacturing applications.
Consistent Uniformity to Improve Control and Performance
Produced through a proprietary manufacturing process, Magna Nitrocellulose MCE meets rigorous quality standards throughout every step of production. This process ensures the membrane has a uniform pore structure and consistent thickness and cosmetic characteristics.
This membrane is cast from a high-quality, nitrocellulose polymer. Its thickness can be controlled to plus or minus 10 microns to accommodate various applications.
GE Nitrocellulose MCE is easily blocked giving a very low background. This aids in the detection of low-level analytes and makes this membrane ideal for use in lateral flow assays and dot/slot blotting. The large, consistent pore structure promotes fast wick rates and ensures rapid test results in diagnostic kit applications
Flexibility for OEM Requirements
GE Nitrocellulose MCE is available in plain or grid rolls from 1 cm (0.39 in) up to 40 cm (16 inches) wide. It is also available in sheets and cut discs that can be customized to meet your application and size requirements. Slitting tolerance is from +/- 0.16 cm (+/- 0.0625 in) Because GE Nitrocellulose MCE is manufactured on-site in GE Osmonics facilities all customization, such as wicking rate and thickness, is easy and cost-effective.
Product Characteristics
Sterilization |
Gamma Irradiation or Ethylene Oxide (EtO) |
USP Class VI Testing |
Passed |
Thickness |
Approximately 6 mil (150 µm) +/- 10 µm |
Extractables |
<4% |
BSA Protein Binding |
Approx. 160 µg/cm² (depending on pore size) |
Maximum Operating Temperature |
180° C (356° F) |
Sealing Compatibility |
Ultrasonic, Heat, Radio Frequency and Insert Molding |
Wicking Rate |
**Time required for an aqueous solution to travel 4 cm. 5.0 µm - 200 sec. 8.0 µm - 120 sec.15.0 µm
- 70 sec. |
Pore Size Range |
0.1 to 15 µm |
Performance Characteristics
Pore Size
|
0.1 µm
|
0.22 µm>
|
0.45 µm>
|
0.8 µm>
|
1.2 µm>
|
5.0 µm>
|
Minimum Bubble Point
psi (kg/cm²)
|
80
(5.62) |
52
(3.66) |
30
(2.11) |
11
(0.77) |
9
(0.63) |
6
(0.42) |
Typical Flow Rate
mL/min/cm²@10psi (0.7 kg/cm²)
|
6.9 |
19 |
51 |
198 |
265 |
650 |
|
For Additional Information
For all your OEM specific applications, GE Osmonics has the product breadth and flexibility to meet your needs, as well as the quality standards to help ensure your success. Contact our OEM GE Osmonics representative today to discuss application requirements, request free product samples and order products. Call 1-800-444-8212 or 952-988-6665, by fax (952) 988-6662. For international, call +1-952-988-6665 or email us. Some of the standard technical questions are already answered in our Frequently